Guide · updated 2026-11-16
Safety data sheets for candles and wax melts
Most hazards in a scented candle come from the fragrance oil. Wax and wicks are usually not classified. Fragrance oils often contain skin sensitisers such as linalool, limonene, citral or coumarin. Many also carry an aquatic classification. Whether your candle needs a safety data sheet, a hazard label or both depends on your market and on who buys from you.
Do you need an SDS?
| Market | The short version |
|---|---|
| European Union | Candles and wax melts are treated as mixtures. If the finished product is classified, it needs a CLP hazard label. An SDS is required for professional recipients, such as shops and wholesalers who ask for one. If the product is not classified but contains a sensitiser at 0.1% or more, you must supply an SDS on request, and the label carries EUH210. |
| Great Britain | The same rules apply through GB CLP and UK REACH. |
| United States | Consumer products used the way a consumer would use them are exempt from OSHA HazCom. Retailers, distributors and marketplaces often still ask for an SDS. Check what your buyer requires. |
| Canada, Australia | The workplace rules (WHMIS, WHS) cover workplace chemicals. Consumer candles fall under consumer product law, but stockists may still ask for an SDS. |
These are general pointers, not legal advice. When a stockist asks for an SDS, give them one that matches your product. Do not pass on your fragrance supplier's SDS for the neat oil.
Why your candle is not classified like your fragrance oil
At a 10% fragrance load, every substance in the oil is present at a tenth of its strength. A sensitiser at 8% in the oil becomes 0.8% in the candle. That is below the 1% limit for Skin Sens. 1B, so on its own it no longer makes the candle H317. It does still trigger the EUH208 line ("Contains … May produce an allergic reaction."). An oil classified as H411 often ends up as H412 or with no aquatic classification in the candle. This depends on the M-factors and the amounts.
That is why the components in section 3 of the fragrance SDS matter more than the classification in its section 2. Use the components, scaled to your dose. Where the SDS gives a range, use the upper value.
Step by step
- Get the current SDS for every fragrance oil and any dye or additive you use.
- Enter the fragrance as an ingredient at your load, for example 8% of the finished candle. Paste section 3 of its SDS as its components.
- Enter the wax for the rest of the weight. Leave its hazards empty unless its SDS lists any.
- Choose "Solid" as the form. Flammable-liquid classification does not apply to a finished candle. Reed diffusers and room sprays are liquids, so they need a flash point.
- Check the classification and its reasons, then print the label and the SDS.
- Many suppliers also publish "CLP data at 10%" sheets. Compare your result with theirs. If they differ, find out why before you print.
Fragrance load: percent of wax or percent of candle?
Classification uses the percentage of the finished product. If you add 8 g of oil to 100 g of wax, the oil is 8 ÷ 108 = 7.4% of the candle, not 8%.
The label
A classified candle needs these on its CLP label:
- the product name
- the pictograms
- the signal word
- the H- and P-statements
- "Contains" with the sensitisers responsible
- any EUH208 line
- the nominal quantity
- your name, address and telephone number
Pictogram sizes are covered in the CLP label guide. Candle fire-safety pictograms (EN 15494) are a separate, voluntary standard that many sellers add.
Open the generator
Sources
- Regulation (EC) No 1272/2008 (CLP), Annex I and Annex II (EUH208, EUH210).
- REACH Article 31(1) and 31(3).
- OSHA 29 CFR 1910.1200(b)(6)(ix), consumer product exemption.